II. Handing Precautions
5
● To prevent the risk of electric shock, the power plug must be plugged into a matching outlet and
grounded in good condition.
● Never try to lift a load higher than the rated cap.
● Never hitch a ride on the hook, sling or load being moving.
● Winches are not to be used for lifting or lowering people.
● Don’t work, walk or stand under an operating winch.
● Always remain in control. Never neglect the winch while actually hoisting a load.
● While working, never stand under a lifting load or within the conveying area.
● Always look up when working around winch, there is potential danger overhead.
● Never gravitate a load free.
● Be sure to lift a load vertically. Slack may allow wires to be caught in the drum.
● Prior to starting of use, carry out the daily checking without fail, and after confirming the safety
of function.
● If having a counter rotation incurred, make sure to correct its rotation direction.
● Prior to lifting. Make sure to have a precise performance of brake. If any malfunction of brake
happened, stop the operation immediately.
● When load suspended in air, it will not allow to be welding.
● Wire rope with one or more of the following defects shall be removed or replaced immediately.
1) kink, 2) distortion, 3) corrosion,
4) Broken wires more than 10%, 5). Decreasing of diameter more than 7%
● Stop the operation if there is any queer noise or vibration in the gear box to be happened.
● Do not connect the wire rope with the grounding of welding machine.
● While welding, do not have any contact with the welding objects because of having spark.
● Do not pull the switch.
● Never plugging (instant reverse-winding) or inching.
● Do not over the short time ratings of the winch.
● In order to prevent the layer down due to over loosening of rope irregular winding, etc., operate
according to the suitable operating method.
● Use a winch by fixing so securely that the rope around the drum is even.
● Be sure to fix a rope in the center of weight hook.
● Avoid catching the hook or lifting a load on a fixed obstruction.
● Always leave the pendant switch positioned immediately after use.
Winch Model Lifting Capacity
w/Industry plug
Switch Cord
CWS-80 80 kg 1.5 mm
2
x 3C x 5 m
1.25 mm
2
x 6C x 10 m
CWS-160 160 kg 1.5 mm
2
x 3C x 5 m 1.25 mm
2
x 6C x 10 m
CWS-230 230 kg 1.5 mm
2
x 3C x 5 m 1.25 mm
2
x 6C x 10 m
CWS-300 300 kg 1.5 mm
2
x 3C x 5 m 1.25 mm
2
x 6C x 10 m